Daystate 110 compressor stalling out?

Something to check for first. Is there a voltage problem? If the voltage is low current goes up. Are you using a small gauge extension cord? Those are quick easy checks. If you release pressure will the motor start again? When you say stalling does the motor just hum? The more information the easier the troubleshooting. Note I do not have a Daystate comp. But am a long time electrician. Also on my Omega compressor, I need to keep the coolant running even after shutting of at the desired pressure. If I dont let it cool there is a chance the compressor motor will not start.




 
 The motor is trying to turn over the air compressor and something is causing the electric motor to work too hard resulting in a high amp draw which is popping the breaker. It’s not the electric motor it’s the actual compressor . I had similar . You can disassemble the unit rather easily and send just the compressor part for repairs. It happens. 
 
FYI I don't use ANY of my compressors to fill past 4000psi even if they can. That last extra 500psi is a killer. Just like filling the Nova Liberty (Avenger) rated at 4350psi. I just do 3000psi and refill more often. Less stress on the seals. Same with my other high pressure fill guns even my Huben and others as well just fill to 3000psi since I never want to deal with potential leaks.
 
FYI I don't use ANY of my compressors to fill past 4000psi even if they can. That last extra 500psi is a killer. Just like filling the Nova Liberty (Avenger) rated at 4350psi. I just do 3000psi and refill more often. Less stress on the seals. Same with my other high pressure fill guns even my Huben and others as well just fill to 3000psi since I never want to deal with potential leaks.

yeah 4000 then just refill more often is what i do